Code |
Description |
E-000 |
Fuser Temperature Rising Error |
Fuser Temperature does not reach 50C within 120 seconds after turning on. |
E-001 |
Fuser Over Temperature Error |
Fuser Temperature reaches over 230C. |
E-002 |
Fuser Low Temperature Error |
1. Fuser Temperature at the time of turning on was 50 to 100C, but it does not rise up to 120C within 150 seconds after that. |
2. Fuser Temperature at the time of turning on was higher than 100C, but it does not rise up to the setting temperature within 330 seconds after that. |
E-003 |
Fuser Temperature Abnormal Fall Error |
The difference of temperature between center and side of fuser becomes 50C or more. |
E-004 |
Fuser Temperature Abnormal Fall Error |
The Lamp of fuser lights (Signal HEAT1 is “H”) to heat up the Fuser Roller in the ready condition, but even 1C of temperature rise can not be accomplished within 30 seconds. |
E-010 |
Main Motor Error |
The Main Motor Output Detection Signal (MAINM_LD) continues to be “H” for 3 seconds or longer when the Main Motor is rotating. |
E-011 |
Fuser Motor Error |
The Fuser Motor Output Detection Signal (HEATM_LD) continues to be “H” for 3 seconds or longer when the Fuser Motor is rotating. |
E-012 |
Developer Press Motor Error |
The Developer Press Sensor Signal (PRESS_S) does not change to “L” within 30 seconds after turning on. |
E-020 |
Counter Error |
The Counter Connection Detection Signal (COUNT_OPN) continues to be “L” for 1 second or longer after turning on. |
E-031 |
Image Corona Output Error |
The Image Corona Output Detection Signal (IM_LD) continues to be “L” for 1 second or longer when the Image Corona is ON. |
E-032 |
Separation Corona Output Error |
The Separation Corona Output Detection Signal (AC_LD) continues to be “L” for 1 second or longer when the Separation Corona is ON. |
E-033 |
Transfer Corona Output Error |
The Transfer Corona Output Detection Signal (TR_LD) continues to be “L” for 1 second or longer when the Transfer Corona is ON. |
E-034 |
Bias Output Error |
Bias Output Detection Signal (BIAS_LD) continues to be “L” for 1 second or longer when a specified bias is supplied to the corresponding Developer Unit components. |
E-040 |
Cutter Error |
1. The Cutter Home Sensor Signal (MSCUT_L or MSCUT_R) does not change to “H” within 100 millisecond since the Cutter has started the operation. |
2. The Cutter Home Sensor Signal (MSCUT_L or MSCUT_R) does not change to “L” within 1 second since the Cutter has started the operation. |
E-050 |
FPGA Error |
Initialization of FPGA is failed after turning on. |
E-070 |
Developer Unit Set Error |
1. The Connector J-253 is not connected. |
2. The Switch (MS4) is “open” condition, which detects open/close of Engine Unit or Toner Hatch. |
E-080 |
Density Sensor Error |
The default output of Density Sensor reaches less than 0.1V or more than 1.3V. |
E-081 |
Density Sensor Output Error |
The gap between the default output and the standard output of Density Sensor reaches less than 2V. |